Lesson series
Ultimate Electric Circuits Course for Electrical Engineers
Learn the fundamentals of electric circuits from scratch with dozens of examples for electrical engineering students. This course consists of 136 lectures and over 10h total length.
Write your awesome label here.
What's included?
Welcome To Our Course "Complete Electric Circuits Course For Electrical Engineering". This course is designed for absolute beginners who have zero knowledge about electric circuits, I start from zero until you understand all the fundamentals with hundreds of examples !!
What are we going to learn from this course?
What are we going to learn from this course?
-
Fundamentals of electric DC circuits
-
SI units or international Units
-
Definition of the electric charge
-
Definition of the electric current
-
Definition of the electric voltage
-
Definition of the electric power
-
Definition of the electric energy
-
Difference between dependent and independent sources
-
Applications of DC Circuits
-
Know the principle of TV picture tube or CRT
-
Know about the electricity bills calculations
-
Basic laws of Electricity
-
Understand Ohm's law
-
Difference between an Open Circuit and Short Circuit
-
Difference between Fixed and Variable Resistance
-
Definition of Conductance
-
Know difference between series and parallel connection
-
Definition of the Nodes, Branches and loops in Electric circuit
-
Definition of the Kirchhoff's laws
-
Definition of Kirchhoff current law
-
Definition of Kirchhoff voltage law
-
Series resistor and voltage division
-
Know parallel resistor and current division
-
Wye-Delta transformations and vice-versa
-
Understand Applications as Lightning Systems
-
Understand Nodal analysis no voltage source
-
Understand Nodal analysis with voltage sources
-
Understand the supernode
-
Understand Mesh analysis no current Source
-
Understand Mesh analysis with current Sources
-
Understand the supermesh
-
Compare between Nodal and Mesh analysis
-
Understand applications as DC transistor circuits
-
Understand the meaning of the linearity property
-
Use the Superposition theorem
-
Understand Thevenin's theorem
-
Understand Norton's theorem
-
Maximum power transfer
-
Understand the source transformation
-
Understand application as resistance measurement
-
Understand the various types of operational amplifiers
-
Understand ideal op amp, inverting/non-inverting amplifier
-
Understand summing op amp circuit
-
Understand difference op amp circuit
-
Understand cascaded op amp circuit
-
Know the applications of op amp like Digital-to-Analog converter
-
Know the applications of op amp like instrumentation amplifiers
-
Know what is a capacitor
-
Understand how to simplify series capacitors
-
Understand how to simplify parallel capacitors
-
Know what is an inductor
-
Understand practical capacitors and practical inductors
-
Understand how to simplify series inductors
-
Understand how to simplify parallel inductors
-
Know how to get energy stored in capacitor
-
Know how to get energy stored in inductor
-
Know the applications of capacitors and inductor as integrator
-
Know the applications of capacitors and inductor as differentiator
Course Content
-
Basic Concepts
-
Basic Laws
-
Methods of Analysis
-
Circuit Theorems
-
Operational Ampflifiers
-
Capacitors and Inductors
-
Certificate of Completion
6 sections • 136 lectures • 10h 22m total length
Who Is This Course For
- Anyone who wants knowledge about electric circuits or engineers
- Anyone who is interested in Knowing the main concepts of electric circuits
- Anyone who is a student and wants to learn about DC circuits easily
Requirements
- No prior Knowledge about electric circuits
- Passion for Learning and Never Giving up
About Ahmed
I am Ahmed Mahdy an electrical power engineer, I have been an instructor for more than 5 years in electrical engineering, I have helped more than 40,000 students from more than 170 countries achieving their career success with my simple and easy courses. In every one of my courses, you'll see that I am always available and always offer you support through each course. I will join your success and help you through any obstacles.
Courses
Earthing Systems and Power Quality Course
In-depth analysis of the fundamental issues in the PQ discipline considering related standards, practical case studies.
Prof. Dr. Mohamed El-Shimy
Electrical Designing and Drafting Course - Part 2
Learn how to perform various electrical calculations and to use AutoCAD from scratch to professional level (real project included in DWG) in your residential and commercial projects.
Er. Sadiq Hussain
Electrical Designing and Drafting Course - Part 1
Learn from scratch to design residential and commercial projects with electrical transformers, diesel gensets, UPSs, batteries, etc. (electrical theory included).
Er. Sadiq Hussain
The Fundamentals of AC & DC Motors and Generators
The fundamentals of rotating electrical machines: AC & DC electric motors and generators intended both for the novice as well as a review for those who have previously studied the subject matter.
Graham Van Brunt P. Eng., B.Sc.
Fundamentals of power generation, transmission and distribution systems
Fundamental concepts of Electrical Power Engineering (basic concepts, electrical components and the basics of power generation, transmission and distribution).
Emre Bengi
Voltage Drop & Fault Current Analysis Course For Power Engineers
Learn how to calculate voltage drop in single phase, balanced & unbalanced three-phase power systems and short-circuit currents.
Emre Bengi
Generation of High Voltage in AC/DC Power Systems
This course is designed for electrical engineers and students who want to learn the fundamentals of generating different high voltage levels in AC/DC power systems
Ahmed Mahdy
Industrial Automation
From Zero to Hero: Fundamentals of Motor Soft Starters
Learn about soft starters, three phase asynchronous motors, starting curve and importance of smooth start.
Marko Cvrkota
MATLAB Simulink for power electronics, electric circuits & machines, solar and synchronous generators
Learn how to use MATLAB/Simulink for power electronics circuits, electric circuits, electrical machines, solar and synchronous generators.
Ahmed Mahdy
Low-Current Installations Course: Fire Alarm, CCTV, Data, Telephone & MATV Systems
Learn about low-current installations: Fire Alarm, CCTV , Data, Telephone, Sound and MATV Systems
Ahmed Mahdy
PLC Programming Course - Fundamentals of PLC Ladder Programming Using Logixpro Simulator
Learn fundamentals of ladder diagram for PLC by using LogixPro simulator for electrical power and industrial engineering
Ahmed Mahdy
The Substation Fundamentals Course
Course for power engineering students about substations and electric power system (circuit breakers, grounding systems, ring main units, transmission lines, and more!).
Ahmed Mahdy