Course overview

Electrical Designing and Drafting Course (Part 2)

Learn how to perform various electrical calculations and to use AutoCAD from scratch to professional level (real project included in DWG) in your residential and commercial projects.
Write your awesome label here.

 What's included

This course is the second part of a series, “Electrical Designing and Drafting Course.” It introduces the student to various electrical calculations and the comprehensive chapter for learning AutoCAD from scratch to professional level (60 lessons + real project included in DWG). After completing this course, you will have high confidence in your electrical design using AutoCAD. All calculations and explanations are as per the NEC and other international codes and standards.

We strongly advise you to (if you didn't already) take the first part of this course
Section 3:

  • Cables & Cable Sizing: This chapter explores the very important part of electrical design. Introduction of Cables, cable sizes, parts of the cable, types of insulation, important points related to cable, size calculation, etc.
  • Voltage Drop Calculation: Voltage drop calculation is must important during the calculation of cables, in this chapter, you will learn Voltage Drop Calculation in a cable.
  • Short Circuit Calculation: Here we have the Short circuit current capacity calculation for proposed cables, calculate the tripping time of CB.
  • Cable Tray Size Calculation: After cable size calculation we have the concept of cable tray, through which cable runs from one point to another. This chapter explains cable tray size calculation.
  • Earthing: Earthing is very important for any building, electrical equipment, so here you will learn the earthing concept and calculation of earthing pit, strip, rod, etc.
Section 4:

  • AutoCAD (60 Lessons): This section relates to the software part, where this AutoCAD chapter you will learn how to use AutoCAD in a professional manner, control keys, function keys, basic drawing commands, modifying commands, editing commands, dimension commands, block/layer, print commands, etc, plus practice.
  • Assignment: At the end, you have given a Real-Time Project for ground + five floors. You have to do all the calculations for a complete electrical design for this building.

 Course Content

  • Introduction & Course Overview
  • Chapter 14 - Power Cables
  • Chapter 15 - Voltage Drop Calculation
  • Chapter 16 - Short Circuit Calculation
  • Chapter 17 - Cable Trays
  • Chapter 18 - Earthing
  • Chapter 19 - AutoCAD
  • Certificate of Completion
8 Chapters • 89 lectures • 6h 55m total length

 Who Is This Course For

  • Electrical Graduates
  • Other Graduates
  • Electrical Designers
  • Freshers
  • Electrical Operators
  • Developers
  • Site Engineers
  • Facility Maintenance Persons
  • Technicians

 Requirements

  • Passion to learning
  • Basic technical knowledge

Er. Sadiq Hussain

PMC, Electrical Designer and Trainer
About SADIQ
Since 2015 I have experience in the teaching field, Electrical Site Experience in commercial projects, Electrical designing and drafting & Training also.In my small Career; I have executed commercial projects with the excellent team whether in Gujarat, Uttarakhand or Tamil Nadu.I started my career as a Lecturer, then appointed as a Project Management Consultant and Electrical designer, and have a passion to train persons.Hope you will learn much more with me.