Lesson series
Ultimate Course To Electrical Design Drawing Using Autocad, Dialux And ETAP
Learn everything you need to work in electrical distribution field design drawing for electrical power engineers.
Write your awesome label here.
What's included?
Welcome To Our Course "Complete Electrical Design Drawing Using Autocad, Dialux And ETAP". This course is essential for electrical power engineers who want to work in the distribution field; this will guide you from zero even if you don't know anything.
So what are we going to learn in this course?
- In this course, we will learn all of the necessary tools and commands required by electrical power engineers in Autocad. Also, we will learn all of the basic definitions of lighting.
- We will differentiate between different types of electrical drawing, various lighting schemes, and lighting situations.
- We will learn about requirements for a good lighting scheme, maintenance, and utilization factors.
- We will get an overview of the Steps we are going to use for lighting design. Also, we will understand how to use catalogs and photometric data in Dialux.
- We will learn how to do the manual calculation for lighting instead of Dialux.
- We will start Interior Design Drawing by Taking a Factory floor and start creating rooms in Dialux. Then we'll add luminaries to each of these rooms according to the Lux of Each room, start creating control groups, and add them to Emergency and Normal Light scenes.
- We will start wiring using Autocad and connect the luminaries with Wires and connect to panel.
- Then we will add standard sockets and power sockets, do the wiring for them and connect them to the panel.
- We will start doing the panel schedule for our project.
- We will then learn about circuit breakers and cables and how to select them for our project.
- Finally, we will calculate the voltage drop and short circuit analysis using ETAP.
- We are also going to learn about the earthing system and how to design it.
Course Content
-
Introduction To AutoCAD
-
Complete Electrical Design Drawing Of Distribution System
-
Voltage Drop and Short-Circuit Analysis
-
Earthing System Design
-
Certificate of Completion
4 sections • 64 lectures • 8h 5m total length
Who Is This Course For
- Electrical power engineers who want to Learn about Interior Electrical Design
Requirements
- You should have a Computer or Laptop
- You should have an Internet connection for Dialux and Autocad Download
About Ahmed
I am Ahmed Mahdy an electrical power engineer, I have been an instructor for more than 5 years in electrical engineering, I have helped more than 40,000 students from more than 170 countries achieving their career success with my simple and easy courses. In every one of my courses, you'll see that I am always available and always offer you support through each course. I will join your success and help you through any obstacles.
Recommended Courses
Earthing Systems and Power Quality Course
In-depth analysis of the fundamental issues in the PQ discipline considering related standards, practical case studies.
Prof. Dr. Mohamed El-Shimy
Electrical Designing and Drafting Course - Part 2
Learn how to perform various electrical calculations and to use AutoCAD from scratch to professional level (real project included in DWG) in your residential and commercial projects.
Er. Sadiq Hussain
Electrical Designing and Drafting Course - Part 1
Learn from scratch to design residential and commercial projects with electrical transformers, diesel gensets, UPSs, batteries, etc. (electrical theory included).
Er. Sadiq Hussain
The Fundamentals of AC & DC Motors and Generators
The fundamentals of rotating electrical machines: AC & DC electric motors and generators intended both for the novice as well as a review for those who have previously studied the subject matter.
Graham Van Brunt P. Eng., B.Sc.
Fundamentals of power generation, transmission and distribution systems
Fundamental concepts of Electrical Power Engineering (basic concepts, electrical components and the basics of power generation, transmission and distribution).
Emre Bengi
Voltage Drop & Fault Current Analysis Course For Power Engineers
Learn how to calculate voltage drop in single phase, balanced & unbalanced three-phase power systems and short-circuit currents.
Emre Bengi
Generation of High Voltage in AC/DC Power Systems
This course is designed for electrical engineers and students who want to learn the fundamentals of generating different high voltage levels in AC/DC power systems
Ahmed Mahdy
Industrial Automation
From Zero to Hero: Fundamentals of Motor Soft Starters
Learn about soft starters, three phase asynchronous motors, starting curve and importance of smooth start.
Marko Cvrkota
MATLAB Simulink for power electronics, electric circuits & machines, solar and synchronous generators
Learn how to use MATLAB/Simulink for power electronics circuits, electric circuits, electrical machines, solar and synchronous generators.
Ahmed Mahdy
Low-Current Installations Course: Fire Alarm, CCTV, Data, Telephone & MATV Systems
Learn about low-current installations: Fire Alarm, CCTV , Data, Telephone, Sound and MATV Systems
Ahmed Mahdy
PLC Programming Course - Fundamentals of PLC Ladder Programming Using Logixpro Simulator
Learn fundamentals of ladder diagram for PLC by using LogixPro simulator for electrical power and industrial engineering
Ahmed Mahdy
The Substation Fundamentals Course
Course for power engineering students about substations and electric power system (circuit breakers, grounding systems, ring main units, transmission lines, and more!).
Ahmed Mahdy