Course overview
Ultimate course to PLC Lab at home (Arduino, CODESYS)
This course provides hands-on Step by Step experience to integrate, Arduino, PLC and HMI using Modbus TCP by implementing real industrial projects.
Write your awesome label here.
What's included?
This course provides hands-on Step by Step experience to integrate, Arduino, PLC and HMI using Modbus TCP by implementing real industrial projects. Real projects will be designed step by step to help you grasp the concepts.
By the end of this course, you will be able to integrate various technologies to control industrial automation projects in multiple ways, like using Soft-PLC with Arduino and using HMI with Arduino. The materials also contain a lot of videos that will teach you various skills. Stuff like, Ladder logic programming, HMI design, VFD driving and many other cool lectures that you can use to expand the Arduino integration in real industrial automation projects.
By the end of this course, you will be able to integrate various technologies to control industrial automation projects in multiple ways, like using Soft-PLC with Arduino and using HMI with Arduino. The materials also contain a lot of videos that will teach you various skills. Stuff like, Ladder logic programming, HMI design, VFD driving and many other cool lectures that you can use to expand the Arduino integration in real industrial automation projects.
You will use technologies and brands like :
- Arduino
- CodeSys
- Schneider Electric
- Modbus TCP
- VFD (Industrial motor drivers)
And the best part is you will be able to simulate and integrate most of the things without having to buy any expensive industrial automation hardware. However, if you plan to buy the equipment, then you will be able to design your projects since this course will walk you through Programming and schematic of two complete integration projects.
This course will be based on the famous industrial protocol Modbus TCP, where you will learn how to use it in integrating almost any Modbus TCP supported device with Arduino, and just to note, this protocol supported by over 70% of the industrial automation devices and equipment.
Course Content
-
Arduino Integration with CODESYS Soft PLC systems
-
Arduino integration with HMI
-
Learning how to use Modbus TCP with multiple equipment
-
Basic VFD driving using Arduino
-
Design HMI screens in two different software
-
Designing in Ladder Logic
-
Handling Classical VFD devices (Industrial motor drivers)
-
Using Arduino to simulate small size industrial automation projects
-
Certificate of Completion
The two projects designed from scratch in this course we are designed step by step. And besides, by the end of each project, an electrical panel-based demonstration video will be shown to let you see the result not only in simulation but also with real industrial automation - electrical hardware.
4 sections • 37 lectures • 5h 30m total length
Who Is This Course For
- Any enthusiast about expanding Arduino capabilities to real applications
- Anyone curious about integrating arduino with HMI and PLC
- Arduino Hobbyist
- Industrial Automation Designers
- Computer engineers
- Electrical and Electronics engineers
- Control Engineers
- Communication Engineers
Requirements
- Arduino UNO
- Arduino Ethernet shield
- PC/Laptop with Windows
- Some wires and potentiometer
- Optional (8-CH Arduino Relay external card with 5v 700mA minimum power supply)
All software we will use are free so you don't need to worry about obtaining any of them, all the links will be provided, noting that these are very highly professional software used by the biggest companies around the world and are by no mean poorly developed ones.
Mouhammad Hamsho
Electrical and electronics engineer with a passion for programming and systems integration
About Mouhammad
I am an electrical and electronics engineer with a passion for programming and systems integration. I have designed industrial automation projects, from small machines to large production lines and automated factories. I am experienced in programming control panels for PLC / DCS, HMI and SCADA. I have experience with programming platforms from Schneider, ABB, Siemens, Delta and AllenBradley. I teach non-engineers to the best in technical concepts and constructions. I believe that through practice you can learn anything regardless of your preferred one.
Recommended Courses
Earthing Systems and Power Quality Course
In-depth analysis of the fundamental issues in the PQ discipline considering related standards, practical case studies.
Prof. Dr. Mohamed El-Shimy
Electrical Designing and Drafting Course - Part 2
Learn how to perform various electrical calculations and to use AutoCAD from scratch to professional level (real project included in DWG) in your residential and commercial projects.
Er. Sadiq Hussain
Electrical Designing and Drafting Course - Part 1
Learn from scratch to design residential and commercial projects with electrical transformers, diesel gensets, UPSs, batteries, etc. (electrical theory included).
Er. Sadiq Hussain
The Fundamentals of AC & DC Motors and Generators
The fundamentals of rotating electrical machines: AC & DC electric motors and generators intended both for the novice as well as a review for those who have previously studied the subject matter.
Graham Van Brunt P. Eng., B.Sc.
Fundamentals of power generation, transmission and distribution systems
Fundamental concepts of Electrical Power Engineering (basic concepts, electrical components and the basics of power generation, transmission and distribution).
Emre Bengi
Voltage Drop & Fault Current Analysis Course For Power Engineers
Learn how to calculate voltage drop in single phase, balanced & unbalanced three-phase power systems and short-circuit currents.
Emre Bengi
Generation of High Voltage in AC/DC Power Systems
This course is designed for electrical engineers and students who want to learn the fundamentals of generating different high voltage levels in AC/DC power systems
Ahmed Mahdy
Industrial Automation
From Zero to Hero: Fundamentals of Motor Soft Starters
Learn about soft starters, three phase asynchronous motors, starting curve and importance of smooth start.
Marko Cvrkota
MATLAB Simulink for power electronics, electric circuits & machines, solar and synchronous generators
Learn how to use MATLAB/Simulink for power electronics circuits, electric circuits, electrical machines, solar and synchronous generators.
Ahmed Mahdy
Low-Current Installations Course: Fire Alarm, CCTV, Data, Telephone & MATV Systems
Learn about low-current installations: Fire Alarm, CCTV , Data, Telephone, Sound and MATV Systems
Ahmed Mahdy
PLC Programming Course - Fundamentals of PLC Ladder Programming Using Logixpro Simulator
Learn fundamentals of ladder diagram for PLC by using LogixPro simulator for electrical power and industrial engineering
Ahmed Mahdy
The Substation Fundamentals Course
Course for power engineering students about substations and electric power system (circuit breakers, grounding systems, ring main units, transmission lines, and more!).
Ahmed Mahdy